Phototron

Semi Automated Clinical Chemistry Analyser

  • Semi-automated
  • 6 Analytical modes
  • 130 programmable assays
  • 47 common assays pre-programmed
  • Real-time data saving
  • Power off protection
  • Windows operating system
  • 8 Wavelengths
     
     
     
     
     
     
     
     
     
  • Analytical modes:  End point, bichromatic, linear regression, multi-calibration, two point and kinetic

  • Pre-programmed assays: 47

  • No. of programmable assays: 130

  • Optical filters: 340, 405, 500, 546, 578, 600 and 670nm

  • Flow cell: 30ul quartz flow cell or a standard cuvette

  • Display: LCD

  • Printer: Thermal Printer

  • Communication: RS232

  • Power Supply: AC 110v - 240v, 50/60Hz

  • Dimension: 450m(L) x 330mm(W) x 140mm(H)

  • Weight: 10kG

 

Autotron 120

Automated Clinical Chemistry Analyser

  • Fully Automated

  • Up to 100 tests per hour

  • In built PC

  • Windows operating system

  • Easy programming

  • Walkaway operation

  • In built QC program

  • Random Access

  • Micro volume for sample and reagent

  • Liquid level detection 

  • Reagent preheating

  • Collision protection

 
 
 
 
 
 
 
 
 
SPECIFICATIONS
  • Test method - End point, two point and rate methods

  • Computations - Factor method, single point calibration, multipoint calibration, linear regression and non-linear regression

  • Optical filters - 340, 405, 450, 510, 546, 578, 600 and 670 nm

  • Reagent positions – 26

  • Sample positions - 9

  • Light source - 12v / 20w long life halogen lamp

  • Display - LCD

  • Printing - Internal printer and optional external printer

  • Working voltage - AC. 100v / 240v 50/60 Hz

  • Max power – 350 Watt

  • Weight – 45Kg

  • Dimensions - 640mm(L) x 480mm(W) x 510mm(H)

  • Communication - USB, PS-2 Barcode

  • Power Supply - AC220V±22V, 50Hz±1Hz

  • Dimension - 550mm x 405mm x 347mm

 

Autotron 240

Automated Clinical Chemistry Analyser

  • Fully Automated

  • Random Access

  • Easy programming

  • Walkaway operation

  • 8 Step Washing System

  • Refrigerated reagent compartment 

  • Pre-diluent function for sample

  • Low reagent consumption

  • Up to 100 tests per hour

  • In built PC

  • Windows operating system

  • User Friendly Software

  • Collision protection

  • Reagent preheating

  •  8 Wavelengths

  •  Totally open system

  •  Up to 240 tests per hour

 

Autotron 420 ISE

Automated Clinical Chemistry Analyser

  • 360 Tests/hour, up to 540 tests/hour with ISE  (optional)

  • Grating system with 12 wavelengths

  • Built-in barcode reader (optional)

  • 8 steps washing system

  • Bi-direction LIS Interface

  • Tailor made reagents from Prestige Diagnostics

Primary System Functions
  • Automatic, Random Access

  • STAT sample priority, available for all sample position barcode scanners for sample and reagent Bi-direction LIS interface (HL7)

  • Throughput -  360 tests/hour (single and dual reagent). Up to 540 tests/hour with ISE (K*, Na*, CI)

  • Principle -  Colorimetric, Turbidimetric

  • Methodology - End-point, Two-point, Kinetic Discrepant Value Single/Dual/Triple/ Quadruple reagent chemistries Monochromatic / Bichromatic

  • Programming - Open system with defined profiles and calculation assays

Sample/Reagent Handling
  • 2 Reagent probes, 1 sample probe
    Sample tray - 100 positions
    Regent tray - 80 refrigerated positions
    Refrigeration temperature - 2 - 10°C
    Reagent volume - 20 - 350 µL, 1µL adjustable
    R1 -  150 - 350 µl, 1µL adjustable
    R2 - 20—250 µl, 1 µl adjustable
    Support R3 and R4
    Sample volume - 2 - 45 µl, 0.1 µl adjustable
    Sample and Reagent probe -
    Collision protection, liquid level detection and
    inventory checking

  • Probe Cleaning  - Automatic washing both interior and exterior, carryover <0.1%
    Pre-heating for reagent
    Auto dilution - 3-150 times
    Built-in reagent/sample barcode reader (optional)

Reaction System
  • Reaction Positions  - 100 cuvettes

  • Cuvette -  Optional length 5mm

  • Reactional volume - 150 - 500µL

  • Reactional temperature - 37°C, ±0.1°C

  • 2 mixing probes

  • 8 steps auto-washing system

Measuring and Optical System
  • Light Source - Halogen tungsten lamp

  • Photometer -  Grating photometry

  • Wavelengths - 340nm, 405 nm

  •                         450nm, 505nm, 540nm, 570nm, 600nm, 635nm,

  •                         670nm 700nm, 760nm, 795nm

  • Absorption range - 0 - 2.500Abs

  • Resolution - 0.0001Abs

Working Condition
  • Power Supply - 100—240 V, AC  50/60 Hz, 1500w

  • Temperature -  10°C—30°C

  • Humidity - 40% - 85%

  • Water consumption - ≤20 L/hour

  • Dimension - 1150mm (L)

  •                      *726.5mm (W)

  •                      *1150mm (H)